Color OLED display can connect PC finger pulse oximeter with USB
|
Supply Ability: |
36000/units per year |
Related proudcts |
pulse oximeter, finger pulse oximete, portable pulse oxime, |
Specifications |
Finger Pulse oximeter |
Price Term: |
FOB |
Port of loading: |
Beijing |
Minimum Order |
5units |
Unit Price: |
30-40 |
|
Instructions for pulse oximeter: Principle of the SW50D+ Pulse Oximeter is as follows: Photo electric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & RecordingTechnology, the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports(It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc. Features for pulse oximeter: -Integrated with SPO2 probe and processing display module. -Can be used in: hospital, home, community medicaltreatment, sports healthcare, etc. -Can measure SPO2 and PR accurately -SPO2 and PR display, PR waveform and bargraph display -Battery voltage low indication -Four directions and six modes -Low power consumption; shut off automatically when no signal. -USB port, sync with PC based analysis software. -Built-in memory, store more than 24 hours patient data. -Small volume(58.5(L) x 31(W) x32(H) mm)light,convenient to carry
Technical Parameters:
Display mode 1.0' double Color OLED display Screen resolution 128*64 Pixel SpO2 Measuring Range 0%~100%, (the resolution is 1%) Accuracy 70%~100%: ¡À2%,Below 70% unspecified PR Measuring Range 30bpm~250bpm, (the resolution is 1bpm) Accuracy ¡À2bpm or ¡À2% (select larger) Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%.SpO2 error is ¡À4%, pulse rate error is ¡À2 bpm or ¡À2% (select larger). Resistance to surrounding light The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ¡À1%. Power Consumption less than 80mA Voltage DC 2.6V~3.6V Power Supply 1.5V (AAA size) alkaline batteries ¡Á 2 Battery working hour Theoretical number is 30 hours. Safety type Interior Battery,BF Type
|
Company: |
Qinhuangdao sanwinmed co.,ltd
|
Contact: |
Ms. Judy xie |
Address: |
408/5 Xinglongshangfu E&T Development zone Qinhuangdao Hebei ,066004,P.R.China |
Postcode: |
|
Tel: |
8585800 |
Fax: |
8585800 |
E-mail: |
|
|
|
|